Aux AC Error Codes and Troubleshooting
Aux AC Error Codes and Troubleshooting
1.HS(Y) HSA(Y) HSB(Y) HSF (Y) HV(Y) HVA(Y) digital display for the series air-conditioner faults:
Error Codes | Problem |
---|---|
E4 | PG motor feedback is abnormal. The display precedence level: 1 |
E1 | Plastic temp sensor is abnormal. The display precedence level: 2 |
E3 | Copper temp sensor is abnormal (indoor). The display precedence level: 3 |
E2 | Copper temp sensor is abnormal (outdoor). The display precedence level: 4 |
2. H (Except KFR-25G/H) H1 HA HB series faults display:
- Fault source: PG motor feedback is abnormal
- Display mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault source: Plastic temp sensor is abnormal
- Display mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault source: Copper temp sensor is abnormal (indoor)
- Display mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
- Fault source: Copper temp sensor is abnormal (indoor)
- Display mode: Timing light twinkles 1 times in every 1 seconds
- The display precedence level: 4
3. H(Y) Model air conditioner fault display:
- Fault source: PG motor feedback is abnormal
- Display mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault source: Plastic temp sensor is abnormal
- Display mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault source: Copper temp sensor is abnormal (indoor)
- Display mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
- Fault source: Copper temp sensor is abnormal (outdoor)
- Display mode: Timing light twinkles 1 times in every 1 seconds
- The display precedence level: 4
4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac faults:
- Fault source: PG motor feedback is abnormal
- Display mode: E4
- The display precedence level: 1
- Fault source: Plastic temp sensor is abnormal
- Display mode: E1
- The display precedence level: 2
- Fault source: Copper temp sensor is abnormal (indoor)
- Display mode: E3
- The display precedence level: 3
5. All of the other E series except EA EC EM EY EZ EAA EAD:
- Fault source: PG motor feedback is abnormal
- Display mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault source: Plastic temp sensor is abnormal
- Display mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault source: Copper temp sensor is abnormal (indoor)
- Display mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
6. QA QB QD digital display series ac faults:
- Fault source: PG motor feedback is abnormal
- Display mode: E4
- The display precedence level: 1
- Fault source: Plastic temp sensor is abnormal
- Display mode: E1
- The display precedence level: 2
- Fault source: Copper temp sensor is abnormal
- Display mode: E3
- The display precedence level: 3
- Fault source: Over-current oprotection
- Display mode: E6
- The display precedence level: 4
7. QC QQ light display series air-conditioner faults:
- Fault source: PG motor feedback is abnormal
- Display mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault source: Plastic temp sensor is abnormal
- Display mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault source: Copper temp sensor is abnormal
- Display mode: Timing light twinkles 3 times in every 8 seconds
- The display precedence level: 3
- Fault source: Over-current oprotection
- Display mode: Timing light twinkles 6 times in every 8 seconds
- The display precedence level: 4
8. Faults display of 18000BTU~24000BTU wall unit series ac non-digital tube displays:
- Fault source: PG motor feedback is abnormal
- Display mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- appearance: System turns off
- Fault source: Plastic temp sensor is abnormal
- Display mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
- appearance: System turns off
- Fault source: Copper temp sensor is abnormal
- Display mode: Timing light twinkles 8 times in every 8 seconds
- The display precedence level: 4
- appearance: System doesn’t turns off
Digital tube displays:
- Fault source: PG motor feedback is abnormal
- Display mode: E1
- The display precedence level: 2
- appearance: System turns off
- Fault source: Plastic temp sensor is abnormal
- Display mode: E3
- The display precedence level: 3
- appearance: System turns off
- Fault source: Copper temp sensor is abnormal
- Display mode: E2
- The display precedence level: 4
- appearance: System doesn’t turn off
- E1: Temperature sensor of air intake fault
- E2: Temperature sensor of outdoor coil fault
- E3: Temperature sensor of indoor coil fault
- E4: PG motor of indoor unit feedback fault
- Self-check code of luminotron: Flicker 1 time/1s
- Digital self-check code: Indicates “dF“or defrosting indicator displays
- Self-check code of luminotron: Flicker 1 time/3s
- Digital self-check code: Fan motor picture not running
- Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
- Digital self-check code: E2/(L2)
- Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
- Digital self-check code: E3/(L1)
- Self-check code of luminotron: Flicker 4 times/6s (luminating)
- Digital self-check code: E4/(E5)
- Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
- Digital self-check code: E5/(L6)
- Self-check code of luminotron: Flicker 6 times/8s
- Digital self-check code: E6
- Self-check code of luminotron: Flicker 7 times/9s
- Digital self-check code: E7
- Self-check code of luminotron: Flicker 8 times/10s
- Digital self-check code: E8
- Self-check code of luminotron: Flicker 9 times/11s
- Digital self-check code: E9
AUX Air Conditioning Wall Mounted Error Codes
Self-check information: Hint to defrosting
Self-check information: Hint to defense against cold wind
Self-check information: Failure of room temperature sensor
Self-check information: Failure of coiled pipe sensor
Self-check information: Abnormality of outdoor unit
Self-check information: Without feedback of internal fan motor
Self-check information: Zero crossing signal without current
Self-check information: External feedback failure
Self-check information: Overheat protection
Self-check information: Water pump failure
Troubleshooting Guide
Problem: The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on
Cause: Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the signal is well received.
Problem: The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.
Cause: If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.
Problem: The compressor works discontinuously at dehumidifying mode.
Cause: The air-conditioner will automatically control the working of the compressor according to the inside temperature
Problem: The air-conditioner dose not work while the LED display is on.
Cause: The TIMER is set with the air-conditioner,it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition.
Problem: The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.
Cause: The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.