Daikin Error Codes and Troubleshooting
Daikin Error Codes and Troubleshooting
Error Codes | Problem |
---|---|
00 | Normal |
UA | Indoor-outdoor Unit Combination Fault |
U0 | Refrigerant Shortage |
U2 | Drop Voltage Or Main Circuit Overvoltage |
U4 | Failure Of Transmission (Between Indoor Unit And Outdoor Unit) |
A1 | Indoor Pcb Defectiveness |
A5 | High Pressure Control Or Freeze-up Protector |
A6 | Fan Motor Fault |
C4 | Faulty Heat Exchanger Temperature Sensor |
C9 | Faulty Suction Air Temperature Sensor |
EA | Cooling-heating Switching Error |
E1 | Circuit Board Fault |
E5 | OL Started |
E6 | Faulty Compressor Start Up |
E7 | DC Fan Motor Fault |
F3 | High Temperature Discharge Pipe Control |
F6 | High Pressure Control (In Cooling) |
H0 | Sensor Fault |
H6 | Operation Halt Due To Faulty Position Detection Sensor |
H8 | DC Current Sensor Fault |
H9 | Faulty Suction Air Temperature Sensor |
J3 | Faulty Discharge Pipe Temperature Sensor |
J6 | Faulty Heat Exchanger Temperature Sensor |
L3 | Electrical Parts Heat Fault |
L4 | High Temperature At Inverter Circuit Heatsink |
L5 | Output Overcurrent |
P4 | Faulty Inverter Circuit Heatsink Temperature Sensor |
Led On Outdoor Unit PCB
2- Daikin L Series AC Error Codes:
Error Codes | Meaning |
---|---|
System Error Codes | |
00 | Normal |
U0 | Refrigerant shortage |
U2 | Low-voltage detection or over-voltage detection |
U4 | Signal transmission error (between indoor unit and outdoor unit) |
UA | Unspecified voltage (between indoor unit and outdoor unit) |
Indoor Unit Error Codes | |
A1 | Indoor unit PCB abnormality |
A5 | Freeze-up protection control or heating peak-cut control |
A6 | Fan motor or related abnormality |
C4 | Indoor heat exchanger thermistor or related abnormality |
C9 | Room temperature thermistor or related abnormality |
Outdoor Unit Error Codes | |
E1 | Outdoor unit PCB abnormality |
E5 | OL activation (compressor overload) |
E6 | Compressor lock |
E7 | DC fan lock |
E8 | Input overcurrent detection |
EA | FourWay valve abnormality |
F3 | Discharge pipe temperature control |
F6 | High pressure control in cooling |
H0 | Compressor system sensor abnormality |
H6 | Position sensor abnormality |
H8 | DC voltage / current sensor abnormality - CT or related abnormality |
H9 | Outdoor temperature thermistor or related abnormality |
J3 | Discharge pipe thermistor or related abnormality |
J6 | Outdoor heat exchanger thermistor or related abnormality |
L3 | Electrical box temperature rise |
L4 | Radiation fin temperature rise |
L5 | Output overcurrent detection |
P4 | Radiation fin thermistor or related abnormality |
U7 | Signal transmission error on outdoor unit PCB |
Indoor Unit PCB Abnormality;
Remote Controller Display: A1
Supposed Causes:
- Wrong models interconnected
- Defective indoor unit PCB
- Disconnection of connector
- Reduction of power supply voltage
Remote Controller Display: A5
Supposed Causes:
- Short-circuited air
- Clogged air filter of the indoor unit
- Dust accumulation on the indoor heat exchanger
- Defective indoor heat exchanger thermistor
- Defective indoor unit PCB
Remote Controller Display: A6
Supposed Causes:
- Layer short inside the fan motor winding
- Breaking of wire inside the fan motor
- Breaking of the fan motor lead wires
- Defective capacitor of the fan motor
- Defective indoor unit PCB
Remote Controller Display: C4, C9
Supposed Causes:
- Disconnection of connector
- Defective thermistor
- Defective indoor unit PCB
Remote Controller Display: U0