Carrier Air Conditioner Error Codes
Carrier Air Conditioner Error Codes
The printed circuit boards existing inside the indoor unit are equipped with self-diagnostic function to detect malfunction and automatically stops the operation at the air conditioner after blinking of power or timer led as per malfunction.
Wall Mounted Air Conditioner Error Codes
Indoor Error Codes:
Error Code: E0 Indoor unit EEPROM parameter error
Error Code: E1 Indoor / outdoor units communication error
Error Code: E3 Indoor fan speed has been out of control
Error Code: E4 Indoor room temperature sensor T1 open circuit or shortcircuit
Error Code: E5 Evaporator coil temperature sensor T2 open circuit or short circuit
Error Code: EC Refrigerant Leakage Detection
Error Code: F1 Outdoor ambient temperature sensor T4 open circuit or short circuit
Error Code: F2 Condenser coil temperature sensor T3 open circuit or short circuit
Error Code: F3 Compressor discharge temperature sensor T5 open circuit or short circuit
Error Code: F4 Outdoor unit EEPROM parameter error
Error Code: F5 Outdoor fan speed has been out of control
Error Code: P0 IPM malfunction or IGBT over-strong current protection
Error Code: P1 Over voltage or over low voltage protection
Error Code: P2 High temperature protection of compressor top diagnosis and solution
Error Code: P4 Inverter compressor drive error
Error Code: P5 Mode conflict
Error Code: P6 Compressor voltage protection
Outdoor Error Codes:
Error Code: E0 Outdoor EEPROM malfunction
Error Code: E2 Indoor/outdoor units communication error
Error Code: E3 Communication malfunction between IPM board and outdoor main board
Error Code: E4 Open or short circuit of outdoor unit temperature sensor
Error Code: E5 Voltage protection
Error Code: E8 Outdoor fan speed malfunction
Error Code: F1 No A Indoor unit coil outlet temperature sensor or connector of sensor is defective
Error Code: F2 No B Indoor unit coil outlet temperature sensor or connector of sensor is defective
Error Code: F3 No C Indoor unit coil outlet temperature sensor or connector of sensor is defective
Error Code: F4 No D Indoor unit coil outlet temperature sensor or connector of sensor is defective
Error Code: F5 No E Indoor unit coil outlet temperature sensor or connector of sensor is defective
Error Code: P1 High pressure protection
Error Code: P2 Low pressure protection
Error Code: P3 Current protection of compressor
Error Code: P4 Temperature protection of compressor
Error Code: P5 High temperature protection of condenser
Error Code: P6 IPM module protection
Comments
Post a Comment