Gree Ductless Heat Pump Error Codes
Gree Ductless Heat Pump Error Codes
Models: GWH09KF-A3DNB1A / GWH12KF-A3DNB1A/ GWH09KF-D3DNB1C/ GWH12KF-D3DNB1C/ GWH18KG-D3DNB1C/ GWH24KG-D3DNB1A
Models: GWH09KF-A3DNB1A / GWH12KF-A3DNB1A/ GWH09KF-D3DNB1C/ GWH12KF-D3DNB1C/ GWH18KG-D3DNB1C/ GWH24KG-D3DNB1A
Gree AC Remote Control Display |
Gree Ductless Heat Pump Error Codes |
Gree AC Remote Control Display |
Error Codes | Possible Causes |
---|---|
C5 | Indoor Configuration Jumper/Missing Configuration Jumper on Indoor Control Board |
LP | Indoor/Outdoor Mismatch/Indoor and Outdoor Units Do Not Match |
E5 | High Current Protection/Power Supply is not Stable and Voltage Range is too Large |
E6 | Communication Error/Mis-wired or Communication Failure |
F1 | Indoor Air Temp. Thermistor/Bad Connection, or Indoor Air Sensor Failure |
F2 | Indoor Coil Temp. Thermistor/Bad Connection, or Indoor Coil Sensor Failure |
F3 | Outdoor Air Temp. Thermistor/Bad Connection, or Outdoor Ambient Sensor Failure |
F4 | Outdoor Coil Temp. Thermistor/Bad Connection, or Outdoor Coil Sensor Failure |
F5 | Compressor Discharge Temp. Thermistor/Bad Connection, or Discharge Sensor Failure |
H3 | Compressor Overload Protection/Low Refrigerant Charge |
H5 | IPM Module Protection/IPM Module Temperature Too High |
H6 | Indoor Fan Malfunction/Indoor Fan Stopped or Running too Slow |
H7 | Compressor Synchronism/High Pressure, Low Voltage, or Bad Connections |
U7 | 4-Way Valve Malfunction/Bad Connection, Solenoid Failure, or Valve Malfunction. |